CIF_RAMAN

Version: 0.3.0 (2018-01-05)

  1. RAMAN_DETERMINATION
    1. _raman_determination.method
  2. RAMAN_COMPLEMENTARY
    1. _raman_complementary.id
    2. _raman_complementary.method
    3. _raman_complementary.method_details
  3. RAMAN_PREDICTION
    1. _raman_prediction.id
    2. _raman_prediction.method
    3. _raman_prediction.method_details
    4. _raman_prediction.active_bands
    5. _raman_prediction.mode_count
  4. RAMAN_SPECTRUM
    1. _raman_spectrum.raman_shift
    2. _raman_spectrum.intensity
    3. _raman_spectrum.raw_intensity
    4. _raman_spectrum.intensity_background
    5. _raman_spectrum.intensity_baseline
  5. RAMAN_MEASUREMENT
    1. _raman_measurement.environment
    2. _raman_measurement.environment_details
    3. _raman_measurement.datetime_initiated
    4. _raman_measurement.datetime_terminated
    5. _raman_measurement.pressure
    6. _raman_measurement.temperature
    7. _raman_measurement.background_subtraction
    8. _raman_measurement.background_subtraction_details
    9. _raman_measurement.baseline_correction
    10. _raman_measurement.baseline_correction_details
    11. _raman_measurement.integration_time
    12. _raman_measurement.range_min
    13. _raman_measurement.range_max
  6. RAMAN_MEASUREMENT_DEVICE
    1. _raman_measurement_device.location
    2. _raman_measurement_device.company
    3. _raman_measurement_device.model
    4. _raman_measurement_device.serial_number
    5. _raman_measurement_device.details
    6. _raman_measurement_device.excitation_laser_type
    7. _raman_measurement_device.excitation_laser_type_details
    8. _raman_measurement_device.excitation_laser_wavelength
    9. _raman_measurement_device.resolution
    10. _raman_measurement_device.configuration
    11. _raman_measurement_device.configuration_details
    12. _raman_measurement_device.power_on_sample
    13. _raman_measurement_device.direction_polarization
    14. _raman_measurement_device.spot_size
    15. _raman_measurement_device.diffraction_grating
    16. _raman_measurement_device.optics_type
    17. _raman_measurement_device.optics_type_details
    18. _raman_measurement_device.microscope_system
    19. _raman_measurement_device.microscope_system_details
    20. _raman_measurement_device.microscope_objective_magnification
    21. _raman_measurement_device.microscope_numerical_aperture
  7. RAMAN_MEASUREMENT_DEVICE_CALIBRATION
    1. _raman_measurement_device_calibration.id
    2. _raman_measurement_device_calibration.standard
    3. _raman_measurement_device_calibration.standard_details

RAMAN_DETERMINATION

Data items in the RAMAN_DETERMINATION category record details about the origin of the spectrum data.

_raman_determination.method

The name of the method (or a class of methods) that was used to determine the Raman spectrum.

Values:

ValueDescription
experimentalRaman spectrum was determined in a Raman spectrum measurement experiment.
theoreticalRaman spectrum was determined using theoretical prediction calculations.

RAMAN_COMPLEMENTARY

Data items in the RAMAN_COMPLEMENTARY category record details about the methods that were used to approve the collected Raman spectrum data.

_raman_complementary.id

Value is a unique key to a set of RAMAN_COMPLEMENTARY items in a looped list.

_raman_complementary.method

The name of the method that was used to approve the spectrum.

Values:

ValueDescription
XRDX-ray diffraction.
EDXEnergy dispersive X-ray.
XRFX-ray fluorescence.
SIMSSecondary ion mass spectrometry.
FTIRFourier transform infrared spectroscopy.
NIRNear infrared.
MössbauerMössbauer spectroscopy.
chemical_analysisChemical analysis.
otherDetermined by a technique not in this list.

_raman_complementary.method_details

Human-readable description of the method used given as the _raman_complementary.method data item value.

RAMAN_PREDICTION

Data items in the RAMAN_PREDICTION category record the results of the Raman spectrum predictions.

_raman_prediction.id

Value is a unique key to a set of RAMAN_PREDICTION items in a looped list.

_raman_prediction.method

The analysis method used to predict the active bands.

Values:

ValueDescription
factor_group_theoryFactor group theory.
DFTDensity functional theory.
DFPTDensity functional perturbation theory.
otherDetermined by a technique not in this list.

_raman_prediction.method_details

Human-readable description of the method used given as the _raman_prediction.method data item value.

_raman_prediction.active_bands

Machine parsable expression of the predicted active bands.

_raman_prediction.mode_count

The number of predicted active band modes.

RAMAN_SPECTRUM

Data items in the RAMAN_SPECTRUM category record the results of the Raman spectrum measurements.

_raman_spectrum.raman_shift

The difference between the measured frequency of scattered light and the incident light beam.

Units: reciprocal_centimetres

_raman_spectrum.intensity

The final intensity of the associated Raman shift after the background subtraction and baseline correction operations. It is equal to the _raman_spectrum.raw_intensity data item value if neither background subtraction nor baseline correction operations were carried out.

Units: arbitrary_units

_raman_spectrum.raw_intensity

The intensity of the associated Raman shift before applying the background subtraction or baseline correction. This is the value that is received directly from the measuring device.

Units: arbitrary_units

_raman_spectrum.intensity_background

The intensity background subtraction value of the associated Raman shift.

Units: arbitrary_units

_raman_spectrum.intensity_baseline

The intensity baseline correction value of the associated Raman shift.

Units: arbitrary_units

RAMAN_MEASUREMENT

The CATEGORY of data items that specify the overall spectral measurement information.

_raman_measurement.environment

The environment that the measurement was conducted in.

Values:

ValueDescription
airAir.
reducing_conditionsReducing conditions.
otherEnvironment not in this list.

Default value: 'air'

_raman_measurement.environment_details

Human-readable description of the measurement environment given as the _raman_measurement.environment data item value.

_raman_measurement.datetime_initiated

The date and time (timestamp) recorded at the start of the measurement experiment. The timestamp should preferably be expressed as specified in RFC 3339, however, a date only time (YYYY-MM-DD) is also acceptable.

_raman_measurement.datetime_terminated

The date and time (timestamp) recorded at the end of the measurement experiment. The timestamp should preferably be expressed as specified in RFC 3339, however, a date only time (YYYY-MM-DD) is also acceptable.

_raman_measurement.pressure

The pressure at which the sample was measured.

Units: kilopascals

_raman_measurement.temperature

The temperature at which the sample was measured.

Units: kelvins

_raman_measurement.background_subtraction

Code that specifies if the background subtraction has been applied.

Values:

ValueDescription
noBackground subtraction was not applied.
nAbbreviation for "no".
yesBackground subtraction was applied.
yAbbreviation for "yes".

_raman_measurement.background_subtraction_details

Human-readable description of the background subtraction that has been applied.

_raman_measurement.baseline_correction

Code that specifies if the baseline correction has been applied.

Values:

ValueDescription
noBaseline correction was not applied.
nAbbreviation for "no".
yesBaseline correction was applied.
yAbbreviation for "yes".

_raman_measurement.baseline_correction_details

Human-readable description of the baseline correction that has been applied.

_raman_measurement.integration_time

The exposure time spent acquiring a single Raman spectrum.

Units: seconds

_raman_measurement.range_min

The minimum of the Raman spectra range.

Units: reciprocal_centimetres

_raman_measurement.range_max

The maximum of the Raman spectra range.

Units: reciprocal_centimetres

RAMAN_MEASUREMENT_DEVICE

The CATEGORY of data items that specify the Raman measurement device information.

_raman_measurement_device.location

The physical location of the device at the time of the measurement.

_raman_measurement_device.company

The name of the company that produced the measuring device.

_raman_measurement_device.model

The model of the the measuring device.

_raman_measurement_device.serial_number

The serial number of the the measuring device.

_raman_measurement_device.details

Human-readable description of the measurement device.

_raman_measurement_device.excitation_laser_type

The type of measurement device excitation laser.

Values:

ValueDescription
argon-kryptonArgon-krypton laser.
argonArgon laser.
kryptonKrypton laser.
helium-neonHelium-neon laser.
xenonXenon laser.
nitrogenNitrogen laser.
excimerExcimer laser.
helium-cadiumHelium-cadium laser.
helium-mercuryHelium-mercury laser.
helium-seleniumHelium-selenium laser.
helium-silverHelium-silver laser.
strontium_vaporStrontium vapor laser.
gold_vaporGold vapor laser.
manganeseManganese laser.
rubyRuby laser.
titanium-sapphireTitanium-sapphire laser.
ceriumCerium laser.
chromiumChromium laser.
otherType of excitation laser not in this list.

_raman_measurement_device.excitation_laser_type_details

Human-readable description of the measurement device excitation laser type given as the _raman_measurement_device.laser_type data item value.

_raman_measurement_device.excitation_laser_wavelength

The wavelength of the measurement device excitation laser.

Units: nanometres

_raman_measurement_device.resolution

The resolution of the measurement device.

Units: reciprocal_centimetres

_raman_measurement_device.configuration

The configuration of the measurement device.

Values:

ValueDescription
simpleSimple.
tripleTriple.
otherType of configuration not in this list.

_raman_measurement_device.configuration_details

Human-readable description of the device configuration given as the _raman_measurement_device.configuration data item value.

_raman_measurement_device.power_on_sample

The power that was used on the sample by the measurement device.

Units: milliwatts

_raman_measurement_device.direction_polarization

The direction polarization of the measurement device.

Values:

ValueDescription
unorientedUnoriented.'
Z(XX)ZLaser polarized parallel to the x axis; analyzer set to pass the x axis polarized light.
Z(YY)ZLaser polarized parallel to the y axis; analyzer set to pass the y axis polarized light.
Z(XY)ZLaser polarized parallel to the x axis; analyzer set to pass the y axis polarized light.
Z(YX)ZLaser polarized parallel to the y axis; analyzer set to pass the x axis polarized light.
X(ZZ)XLaser polarized parallel to the z axis; analyzer set to pass the z axis polarized light.
X(YY)XLaser polarized parallel to the y axis; analyzer set to pass the y axis polarized light.
X(ZY)Xlaser polarized parallel to the z axis; analyzer set to pass the y axis polarized light.
X(YZ)XLaser polarized parallel to the y axis; analyzer set to pass the z axis polarized light.
Y(XX)YLaser polarized parallel to the x axis; analyzer set to pass the x axis polarized light.
Y(ZZ)YLaser polarized parallel to the z axis; analyzer set to pass the z axis polarized light.
Y(XZ)YLaser polarized parallel to the x axis; analyzer set to pass the z axis polarized light.
Y(ZX)YLaser polarized parallel to the z axis; analyzer set to pass the x axis polarized light.

_raman_measurement_device.spot_size

The spot size of the device.

Units: micrometres

_raman_measurement_device.diffraction_grating

The diffraction grating of the device.

Units: lines_per_millimetre

_raman_measurement_device.optics_type

The type of the measurement device optics that was used to focus the primary laser beam onto the sample and/or to collect the scattered radiation.

Values:

ValueDescription
microscopeMicroscope.
optical_fiberOptical fiber.
noneNone.
otherType of optics not in this list.

_raman_measurement_device.optics_type_details

Human-readable description of the measurement device type given as the _raman_measurement_device.optics_type data item value.

_raman_measurement_device.microscope_system

The type of the measurement device.

Values:

ValueDescription
dispersiveDispersive.
FTFourier transform.
otherType of microscope system not in this list.

_raman_measurement_device.microscope_system_details

Human-readable description of the microscope system given as the _raman_measurement_device.microscope_system data item value.

_raman_measurement_device.microscope_objective_magnification

The magnification of the microscope objective.

Units: none

_raman_measurement_device.microscope_numerical_aperture

The numerical aperture of the microscope.

Units: none

RAMAN_MEASUREMENT_DEVICE_CALIBRATION

Data items in the RAMAN_MEASUREMENT_DEVICE_CALIBRATION category record details about the calibration of the measuring device.

_raman_measurement_device_calibration.id

Value is a unique key to a set of RAMAN_MEASUREMENT_DEVICE_CALIBRATION items in a looped list.

_raman_measurement_device_calibration.standard

Type of material that was used in the calibration of the device.

Values:

ValueDescription
silicon_waferSilicon wafer.
diamondDiamond.
1,4_bis_(2-methylstyryl)_benzene1,4 bis (2-methylstyryl) benzene.
calciteCalcite
4-acetamidophenol4-acetamidophenol.
benzonitrileBenzonitrile.
cyclohexaneCyclohexane.
polystyrenePolystyrene.
indeneIndene.
neon_lampNeon lamp.
carbon_tertrachlorideCarbon tertrachloride.
otherCalibration standard material not in this list.

_raman_measurement_device_calibration.standard_details

Human-readable description of the material used in the calibration given as the _raman_measurement_device_calibration.standard data item value.